Brand Name : Wayeal

Model Number : AA2300

Place of Origin : Anhui, China

Certification : CE

MOQ : 1 Unit

Price : Negotiate

Packaging Details : Wooden Case

Delivery Time : 35 days

Payment Terms : T/T

Supply Ability : 30 Units/Month

Injection : Manual Or Autosampler

Name : Atomic Absorption Spectrophotometer

Background Correction : D2 Backgraound Correction

Wavelength Range : 185~910nm

Power Supply : AC220V, 50Hz

Data Storage : USB, PC

Light Source : Halogens, Deuterium, Tungsten

Lamp Position : 8

Contact Now

Product Description:

Atomic Absorption Spectrophotometer - AAS

The atomic absorption spectrophotometer (AAS) is a powerful analytical instrument used to determine the concentration of metal elements in a sample. It is widely used in various fields such as soils, food and beverage industry, pharmaceuticals, chemical analysis, water quality and etc. With its precise and reliable results, the AAS atomic absorption spectrophotometer has become an essential tool for scientists and researchers. The atomic absorption spectrophotometer is equipped with advanced technology and features that make it a highly efficient and accurate instrument. It uses the principle of atomic absorption spectroscopy to measure the absorption of light by the atoms in a sample. The amount of absorption is directly proportional to the concentration of the element being analyzed, providing precise and reliable results.

Features:

Technical Parameters:

Atomic Absorption Spectrophotometer Technical Specifications

185-910nm Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer

Product Name

Atomic Absorption Spectrophotometer

Spectral Bandwidth

0.1, 0.2, 0.4, 1.0, 2.0nm

Background Correction

D2 Background Correction

Weight

280kg

Lamp Position

8

Power Supply

AC220V, 50Hz

Data Storage

USB, PC

Light Source

Halogens, Deuterium, Tungsten

Injection

Manual or Autosampler

Optical System

Wavelength Error

±0.15nm

Wavelength Repeatability

≤0.05nm

Wavelength Range

185~910nm

Flame Atomizer

Detection Limit (LOD)

Cu flame method: ≤0.002ug/mL

Repeatability

RSD≤0.25%

Burning Head

Full titanium

Atomizer

High-efficiency glass, all-plastic, stainless steel

Graphite Furnace

Detection Limit

Cd: ≤0.3pg

Repeatability

RSD≤1.5%

Autosampler

Injection Position

108

Linearity

>0.999

Injection Volume

1~200ul

Injection Volume Repeatability

≤0.1%

Repeatability of Result

≤1.5%

Key Features

  • Graphite Atomic Absorption Spectrometer
  • Flame Atomic Absorption Spectrometry
  • AAS-Atomic Absorption Spectrometer

Applications:

The Wayeal Atomic Absorption Spectrophotometer can be used in a variety of applications, including:

1. Environmental monitoring: This instrument can be used to analyze water, soil, and air samples for trace elements, providing crucial information for pollution control and remediation.

2. analysis: The AA2230 is ideal for analyzing the concentration of active ingredients and impurities in pharmaceutical products, ensuring quality control and compliance with regulatory standards.

3. Agricultural testing: With its high sensitivity and accuracy, this instrument is suitable for the analysis of trace elements in fertilizers, plants, and animal tissues, helping farmers optimize their production processes.

4. Food safety: The AA2230 can be used to determine the presence of harmful elements in food products, ensuring they meet safety standards and protecting consumer health.

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm


Product Tags:

Flame Graphite Furnace AAS Spectrophotometer

      

Atomic Absorption Spectrophotometer 185nm

      

Atomic Absorption Spectrophotometer AC220V

      
China Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm wholesale

Flame Graphite Furnace AAS Atomic Absorption Spectrophotometer 185 - 910nm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Wanyi Science and Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)